| Sign In | Join Free | My hardware-wholesale.com |
|
Brand Name : HAIDA
Model Number : 5107-HD
Certification : CE
Place of Origin : china
MOQ : 1set
Price : Negotiable
Payment Terms : L/C,D/A,T/T,D/P,Western Union,MoneyGram
Supply Ability : 30 Sets per Month
Delivery Time : 20 days after order confirmed
Packaging Details : each set protected with resin fiber and PP film, then put into Strong wooden case with operation man
Working Stability : 0.1% Of Total Fluorescence Intensity
Model : CAM-1000
Power Supply : AC 110/220V, 50/60Hz
Measuring Chamber : 439*300*50mm;
Wavenumber Range : 7800~375 cm-1
Detector : Silicon Photodiode
Grating Lines : 1800
Wavelength Repeatability : +/- 0.2nm
Test Time : 100-300 seconds (adjustable)
Deoxygenation Tube : Dedicated to ECD detector
Content Analysis Range : 1ppm~99.99%
Detection Object : Solid
Instrument Resolution : 144±5eV
Spectral Bandwidth : 2nm
Ion Source : EI, EI/CI mixed source, CI (PCI & NCI)
| Attribute | Value |
|---|---|
| Working Stability | 0.1% Of Total Fluorescence Intensity |
| Model | CAM-1000 |
| Power Supply | AC 110/220V, 50/60Hz |
| Measuring Chamber | 439*300*50mm |
| Wavenumber Range | 7800~375 cm-1 |
| Detector | Silicon Photodiode |
| Grating Lines | 1800 |
| Wavelength Repeatability | +/- 0.2nm |
| Test Time | 100-300 seconds (adjustable) |
| Deoxygenation Tube | Dedicated to ECD detector |
| Content Analysis Range | 1ppm~99.99% |
| Detection Object | Solid |
| Instrument Resolution | 144±5eV |
| Spectral Bandwidth | 2nm |
| Ion Source | EI, EI/CI mixed source, CI (PCI & NCI) |
The condom leak detector is designed for rubber sleeves and condom pinhole leakage tests, meeting industry standards including GB 7544, ISO 4074, and ISO 25841.
Visual inspection method: Condoms are filled with a specific water volume and manually observed for leaks.
| Item | Parameters |
|---|---|
| Test position | 10 |
| Water temperature | (10℃~40℃), time (10±2)s |
| Injection volume | (50mL~1000mL) ±10mL (automatic water injection, adjustable volume) |
| DC voltage | (10±0.1)V |
| Voltmeter accuracy | ±0.3mV |
| Precision resistance | (10±0.5)kΩ |
| Dimensions | 1000 mm (L) * 450 mm (W) * 1600 mm (H) |
| Weight | Approx. 125kg |
| Configuration list | Main unit workstation, measuring electrode rod, male condom test heads, female condom K.2 leak test stand |
Founded in 2004, Haida® is the recognized market leader in Dongguan, China for testing equipment. The company specializes in four main manufacturing series: Accelerated Environmental Series (AES), Universal Tensile Machine (UTM), Paper & Packaging (P&P), and Foam, Furniture & Optical (FFO). Haida also provides equipment for Textile & Shoes & Leather, Luggage, Baby carriage & toys, and optical testing applications.
|
|
CAM-1000 Automatic Condom Leak Detector for Solid Samples Images |